01 / Product description

Conductive copper foil tape

COPPER FOIL TAPE WITH CONDUCTIVE ADHESIVE

Conductive copper foil tape combines copper foil with conductive acrylic adhesive for shielding overlaps and electronics bonding requiring the adhesive layer in the electrical path. Connect foil coverage to confirmed conductive contact areas, using slit strips for seams or die-cut patches for component contours. Address surface cleaning, joint support and assembly position together to reduce unsupported areas, wrinkles and misaligned connections.

  • Copper foil and conductive adhesive
  • Shielding overlaps
  • Slitting and die-cut patches

Conductive adhesive can form part of a connection from foil to a compatible conductive surface, but it does not automatically make paint, insulation film or incompatible contact surfaces conductive. Conductive adhesive also does not mean adhesive is coated on both sides.

Construction highlights
Copper foil / Conductive adhesive
Copper foil series thicknesses
30–200 μmSeries reference range; confirm the precise thickness definition and converting combinations separately.
Supply formats
Rolls / Slitting / Die cutting

02 / APPLICATIONS

Product applications

Explore application, converting and assembly methods for the specific area of use.

Product characteristics

PRODUCT FEATURES
  • Conductive adhesive connects the interface path

    Arrange foil, adhesive and bonding surface around the actual contact location so coverage and interface connection work together. Do not check only whether the foil surface is conductive.

  • Overlaps and corners for assembly continuity

    Lay strips flat along the seam outline, arranging joints and corners to reduce pulling, unsupported spans and local misalignment during enclosure closure.

  • Selective bonding without unintended connections

    Include holes, ports and neighbouring-component clearances in the foil outline so conductive material covers only design-specified areas, reducing unintended contact.

  • Shaped supply reduces repeated cutting

    Convert into strips or contoured patches to maintain clear positioning ends and contact areas in repeated assembly, supporting on-site handling and pressing.

Applications

RANGE OF APPLICATION
  • Computer enclosure seam overlaps

    Consider seams, joint support and assembly movements together. Avoid unsupported strips or tensioned joints and maintain bonding over the target contact area.

  • Selective connections on phone electronic components

    Align contact positions between the copper foil, adhesive and component to reduce skewed small pieces, contaminated adhesive and localized unsupported areas.

  • Connections for display components

    Arrange foil around actual contact positions, avoiding moving structures and unintended areas. After assembly, recheck for compressed or pulled-open joints.

  • Transformer shielding connections

    Arrange coverage and adhesive contact to the established connection path, reducing unsupported areas and wrinkles without altering windings or original functional structures.

Validate shielding with the seams, connection paths and assembly structure. Where protective earthing or operating current is involved, qualified personnel must validate against equipment design and applicable requirements. Tape must not replace prescribed protective-earth conductors, terminals or current-carrying connections.

03 / TECHNICAL DATA

Product specifications

Model properties correspond to JTT-CU-35E; optional series dimensions are listed separately. Temperature resistance and peel strength are reference values. Performance depends on bonding and operating conditions; confirm specification combinations for actual supply.

Product model
JTT-CU-35E
Backing
Copper foil
Adhesive type
Conductive acrylic adhesive
Conductive construction
Conductive foil surface; adhesive can support through-adhesive continuity
Copper foil thickness
35 μm
Total thickness
50 μm(0.05 mm)
Peel strength
4–6 N/25 mm
Reference temperature-resistance range
−40~130°C
Series reference thickness range
30–200 μm
Series reference width range
1–380 mm, custom available
Roll length options
25 / 50 m, custom available
Core diameter options
25 / 32 / 38 / 76 mm
Converting support
Slitting / Die cutting / Custom
Supply and converting formats
Jumbo-roll supply / Master-roll supply / Slitting / Die-cutting services
Packaging
Labels / OPP bags / PVC boxes / Cartons / Customisation

04 / WHY JIAOTAOTAO

Why choose us

More than 16 years of industrial tape manufacturing experience,
Connecting materials, converting and delivery at the factory.

JIAOTAOTAO factory exterior and building signage
JIAOTAOTAO · Dongguan manufacturing site

OUR MANUFACTURING BASE

From coating production to finished-product converting.

Coating, drying and winding connect with rewinding, slitting, die cutting, lamination, inspection and packaging to supply roll materials and converted tape parts for industrial applications.

Industrial tape manufacturing experience
16+years
Factory production space
20000㎡
Production sites
3locations
Explore manufacturing capabilities
01 / FACTORY DIRECT

Direct factory supply, direct communication

Discuss materials, specifications and converting requirements directly with production. Coordinate coating and downstream converting together, reducing handovers and connecting purchasing requirements with actual manufacturing.

02 / QUALITY CONTROL

Factory testing room for delivery quality checks

Check material appearance, dimensions and agreed performance items, coordinating finished-product packaging and identification so confirmed requirements are carried through to delivery.

03 / CUSTOM CONVERTING

Custom converting for practical use

Rewinding, slitting, die cutting and lamination support supply as rolls, finished rolls or contoured tape parts, reducing repeated on-site cutting and handling preparation.

04 / ORDER SUPPORT

Coordinated orders, production and delivery

From specification confirmation through production, inspection, packaging and dispatch, we coordinate quantities, packaging and delivery for each order. You can also discuss product-use feedback directly with us.

05 / CONTACT

Contact us

From application location and material selection to slitting and die cutting,
Let's define the copper foil tape converting and supply plan together.

王俊杰 General Manager

+86 135 3707 3358simon@jiaotaotao.com

JIAOTAOTAO (GUANGDONG) NEW MATERIALS CO., LTD.

TAPE & CONVERTING

Materials that suit your actual process.

If specifications are already available, discuss supply and converting directly. If the material is not yet selected, start with the actual application area and progressively determine the material and converting format.

Contact us

Discuss by email

07 / PRACTICAL ANSWERS

Frequently asked questions

Start with common bonding, joint and assembly symptoms to identify practical corrections. Qualified personnel must carry out electrical checks after power disconnection and isolation.

What should I do if the joint conducts only under pressure and becomes unstable when released?

On a de-energised, isolated sample, check for unsupported joints, insufficient support or assembly-related misalignment. Clean and dry compatible contact surfaces, flatten and press again. Qualified personnel should recheck without hand pressure and after assembly using the same method. If hand pressure remains necessary, adjust the contact structure or material selection rather than hiding the issue with layers.

Why is there still no electrical continuity when applied over a painted housing or insulating film?

Conductive adhesive cannot turn an insulating surface into a conductor. Check whether the connection lies within the design-specified conductive contact area and whether coatings, insulation films or contamination interrupt the path. Restore the original connection position; do not scrape protective coatings or move patches to other exposed metal independently.

How should I adjust seams that pull apart after assembly?

Reproduce the closing movement on a de-energized sample to identify tensioned joints, interference and missing support. Restore movement allowance according to the original design and place overlaps in stable contact areas, avoiding unsupported copper foil bridges. After reapplication, check whether joints separate during movement, then recheck the actual connection.

Where should I check if the patch surface is flat but electrical contact remains unstable?

Do not assess appearance alone. Check base-surface high spots, dust, adhesive contamination and sharp foil creases in sequence, ensuring stable support beneath the joint. Replace damaged, contaminated or distorted patches, then apply and press progressively from one end. Recheck the contact path in the complete assembly.

Can extra layers replace the original connecting parts?

Do not replace specified terminals, connectors or protective earthing conductors with stacked tape. Restore original connections and supports first, then use copper foil for designated shielding coverage or functional overlaps. For operating current and protective earthing, qualified personnel must validate against equipment requirements; the name conductive does not establish substitution capability.