01 / Product description

Copper foil tape with non-conductive adhesive

COPPER FOIL TAPE WITH NON-CONDUCTIVE ADHESIVE

Copper foil backing with non-conductive acrylic adhesive provides shielding coverage on electronic components, enclosure seams and designated display areas. The foil provides conductivity and coverage, while the adhesive holds it in place, for structures not requiring through-adhesive conduction. Slit to seam width or die-cut to part contours for clearer coverage positions, interface clearances and assembly handling.

  • Conductive copper foil surface
  • Non-conductive acrylic adhesive
  • Slitting and die-cut patches

Foil-side-only conductivity describes the difference in electrical conduction between the adhesive side and copper foil side, not single-sided or double-sided adhesive coating. If a connection to the bonded metal surface must pass through the adhesive, select a conductive-adhesive type matching the connection solution.

Supply formats
Jumbo rolls / Master rolls / Slitting / Die cutting
Copper foil series thickness range
30–200 μmSeries reference range; confirm the specific grade and thickness definition separately.
Copper foil series slit widths
1–380 mmConfirm the specific model and converting solution.

02 / APPLICATIONS

Product applications

Explore application, converting and assembly methods for the specific area of use.

Product characteristics

PRODUCT FEATURES
  • Copper foil coverage, secured by adhesive

    Lay copper foil over the design-specified shielding area and use the adhesive to hold contact. Route conductivity through the foil and original connection locations; do not treat the adhesive as an electrical connection.

  • Non-conductive adhesive: distinguish the connection path

    For bonding positions that do not require conduction through the adhesive. Handle seams, overlaps and connection points separately, avoiding discovery only after application that the adhesive separates the required contact interface.

  • Contour coverage with functional clearances

    Incorporate clearances for holes, interfaces and surrounding components into the patch outline, keeping copper foil in the required area and reducing excessive coverage and assembly trimming.

  • Roll slitting and patch die cutting

    Use slit strips for seam coverage and shaped patches for repeated assembly. Arrange converting around handling requirements to reduce cutting on site and positioning variation.

Applications

RANGE OF APPLICATION
  • Transformer shielding bonding

    For specified coverage locations not requiring conduction through the adhesive layer. Arrange foil edges, joints and functional clearances to the original design without changing winding or connection structures.

  • Selective shielding of mobile phone electronic components

    Arrange foil patches along component contours and apply progressively from the positioning end to reduce skewed small pieces, wrinkles and coverage of functional areas.

  • Computer enclosure and component seam coverage

    Cover specified seams that do not require connections through the adhesive, in coordination with the existing shielding connection design. Secure adhesion must not be mistaken for electrical continuity across the seam.

  • Coverage of display components

    Match shaped patches to assembly datums, leaving space for ports and moving parts. Keep coverage flat to reduce compression and pulling when the assembly closes.

Validate shielding with the actual seams, connection paths and assembly structure. Qualified personnel must validate protective earth or operating-current connections against equipment design and applicable requirements. Tape names do not replace protective earth conductors, terminals or current-carrying connections.

03 / TECHNICAL DATA

Product specifications

The following dimensions are confirmed custom reference ranges for the copper foil tape series, not specifications available for every model with non-conductive adhesive. Confirm foil thickness, adhesive thickness, total thickness and converting dimensions separately for the specific model.

Product customization specifications

Colour
Confirm for the selected material and converting solution
Thickness (μm)
30–200 μm, customised to requirements
Width (mm)
1–380 mm, custom available
Length (metres)
25 50 Custom
Core diameter (mm)
25 32 38 76 Custom
Adhesive type
Non-conductive acrylic adhesive; confirm the specific formulation and structure by model
Related processes
Die cutting Customisation
Packaging
Labels OPP bags PVC boxes Cartons Custom
Conductivity type
Foil-side-only conductivity: the copper foil surface conducts; the adhesive does not provide through-adhesive conduction

04 / WHY JIAOTAOTAO

Why choose us

More than 16 years of industrial tape manufacturing experience,
Connecting materials, converting and delivery at the factory.

JIAOTAOTAO factory exterior and building signage
JIAOTAOTAO · Dongguan manufacturing site

OUR MANUFACTURING BASE

From coating production to finished-product converting.

Coating, drying and winding connect with rewinding, slitting, die cutting, lamination, inspection and packaging to supply roll materials and converted tape parts for industrial applications.

Industrial tape manufacturing experience
16+years
Factory production space
20000㎡
Production sites
3locations
Explore manufacturing capabilities
01 / FACTORY DIRECT

Direct factory supply, direct communication

Discuss materials, specifications and converting requirements directly with production. Coordinate coating and downstream converting together, reducing handovers and connecting purchasing requirements with actual manufacturing.

02 / QUALITY CONTROL

Factory testing room for delivery quality checks

Check material appearance, dimensions and agreed performance items, coordinating finished-product packaging and identification so confirmed requirements are carried through to delivery.

03 / CUSTOM CONVERTING

Custom converting for practical use

Rewinding, slitting, die cutting and lamination support supply as rolls, finished rolls or contoured tape parts, reducing repeated on-site cutting and handling preparation.

04 / ORDER SUPPORT

Coordinated orders, production and delivery

From specification confirmation through production, inspection, packaging and dispatch, we coordinate quantities, packaging and delivery for each order. You can also discuss product-use feedback directly with us.

05 / CONTACT

Contact us

From application location and material selection to slitting and die cutting,
Let's define the copper foil tape converting and supply plan together.

王俊杰 General Manager

+86 135 3707 3358simon@jiaotaotao.com

JIAOTAOTAO (GUANGDONG) NEW MATERIALS CO., LTD.

TAPE & CONVERTING

Materials that suit your actual process.

If specifications are already available, discuss supply and converting directly. If the material is not yet selected, start with the actual application area and progressively determine the material and converting format.

Contact us

Discuss by email

07 / PRACTICAL ANSWERS

Frequently asked questions

Find solutions to common bonding, seam and assembly symptoms. Qualified personnel must perform electrical checks after power disconnection and energy isolation.

What if the foil surface does not conduct to the metal underneath after application?

Confirm the connection path first on a de-energised, isolated sample. Non-conductive-adhesive copper foil tape does not provide through-adhesive continuity, so a firmly bonded foil does not establish electrical connection to the underlying metal. If the design needs this path, choose suitable conductive-adhesive copper foil or retain the original specified connection method. Pressure or repeated layers do not replace structural adjustment.

How should an overlap between two sections of copper foil tape with non-conductive adhesive be handled?

Determine whether the seam needs coverage alone or also electrical continuity. Do not assume current passes through the adhesive when its face overlaps another copper foil section. Prefer continuous foil shaped to the coverage area where possible. If sections are necessary, handle joints according to the original connection design, then have qualified personnel check the actual assembled path.

How can lifted copper foil edges around enclosure corners be improved?

Clean and dry contact surfaces, then check for unsupported spans or excessive tension at corners. Lay the foil naturally in sections along the contour, ending on a flat area that can be pressed firmly. Close the enclosure and check whether components lift it. Replace creased or contaminated patches rather than stretching them into alignment.

What should I do if small copper foil patches misalign or touch ports?

Include hole and interface clearances in the die-cut outline and use the same positioning datum as the workpiece. Start at the positioning end, then progressively release the rest to avoid premature full-surface contact. Do not pull misaligned copper foil back into position; replace distorted or contaminated patches before reapplication.

Can non-conductive adhesive make this suitable as electrical insulating tape?

Non-conductive adhesive alone does not establish a rated electrical insulation layer. The product surface remains conductive copper foil; contact with components, terminals or bare conductors may change the original connections. Retain insulation materials and safety clearances required by the equipment design. Confirm coverage boundaries on a de-energised sample before assembly inspection.