01 / Product description

Aluminium foil tape

ALUMINIUM FOIL TAPE

Aluminium foil backing with conductive acrylic adhesive for duct-seam coverage, moisture-resistant bonding areas, surface patching and electronics shielding locations. Apply foil in sections along actual contours, or slit and die-cut to designated areas for easier control of seams, edges and clearances.

  • Aluminium foil backing
  • Conductive acrylic adhesive
  • Seam and surface coverage

Aluminium foil is the metal carrier and pressure-sensitive adhesive is the bonding layer. Select standard acrylic or conductive acrylic adhesive separately; foil appearance cannot establish through-adhesive conductivity.

Supply formats
Jumbo rolls / Master rolls / Slitting / Die cutting
Product thickness
30–200 μmSelect according to the specific material, application and converting requirements.
Slit width
1–1240 mm

02 / APPLICATIONS

Product applications

Explore application, converting and assembly methods for the specific area of use.

Product characteristics

PRODUCT FEATURES
  • Aluminium foil surface coverage

    Lay aluminium foil strips or patches over the designated area, arranging seams and corners for a clear coverage boundary.

  • Conductive acrylic adhesive

    For assemblies requiring electrical continuity, arrange bonding and connections around the foil surface, adhesive layer and contact positions.

  • Seam bonding support

    After cleaning and drying, firmly bond the tape on both sides of the seam to reduce unsupported edges and subsequent lifting.

  • Slitting and die-cutting support

    Prepare strips and patches for the seam width or coverage contour to reduce repeated on-site cutting and joining.

Applications

RANGE OF APPLICATION
  • Duct joint coverage

    Apply in sections along clean, dry seams, firmly contacting both sides to reduce unsupported areas and edge lifting.

  • Moisture protection in non-food-contact kitchen areas

    Apply covering on dry surfaces and press edges down progressively to reduce moisture entry through unbonded seams.

  • Non-load-bearing surface covering repairs

    Remove loose material before covering local surface areas, bonding the patch to intact, dry surrounding material.

  • Selective shielding in electronics assembly

    Make patches to specified shielding contours, planning contact locations and functional clearances for consistent application.

Validate sealing, moisture protection, repair and conductive uses for their respective models and operating conditions. Single-/double-conductive labels do not establish continuity at every interface. Surface covering does not replace pressure-bearing, load-bearing or safety-critical structural repairs, nor establish long-term immersion protection or food-contact suitability.

03 / TECHNICAL DATA

Product specifications

Confirm the relevant model's physical properties according to the selected material and converting solution. Do not apply another tape's data to this product.

Product customization specifications

Backing
Aluminium foil
Adhesive-coated sides
Single-sided
Release layer
Optional release paper
Temperature resistance
300°C; continuous-use duration and suitable operating conditions must be confirmed for the actual application
Colour
Confirm for the selected material and converting solution
Thickness (μm)
30–200 μm, customised to requirements
Width (mm)
1–1240 mm, custom options available
Length (metres)
50 100 Custom
Core diameter (mm)
25 32 38 76 Custom
Adhesive selection
Acrylic pressure-sensitive adhesive / Conductive acrylic pressure-sensitive adhesive
Related processes
Die cutting Customisation
Packaging
Labels OPP bags PVC boxes Cartons Custom

04 / WHY JIAOTAOTAO

Why choose us

More than 16 years of industrial tape manufacturing experience,
Connecting materials, converting and delivery at the factory.

JIAOTAOTAO factory exterior and building signage
JIAOTAOTAO · Dongguan manufacturing site

OUR MANUFACTURING BASE

From coating production to finished-product converting.

Coating, drying and winding connect with rewinding, slitting, die cutting, lamination, inspection and packaging to supply roll materials and converted tape parts for industrial applications.

Industrial tape manufacturing experience
16+years
Factory production space
20000㎡
Production sites
3locations
Explore manufacturing capabilities
01 / FACTORY DIRECT

Direct factory supply, direct communication

Discuss materials, specifications and converting requirements directly with production. Coordinate coating and downstream converting together, reducing handovers and connecting purchasing requirements with actual manufacturing.

02 / QUALITY CONTROL

Factory testing room for delivery quality checks

Check material appearance, dimensions and agreed performance items, coordinating finished-product packaging and identification so confirmed requirements are carried through to delivery.

03 / CUSTOM CONVERTING

Custom converting for practical use

Rewinding, slitting, die cutting and lamination support supply as rolls, finished rolls or contoured tape parts, reducing repeated on-site cutting and handling preparation.

04 / ORDER SUPPORT

Coordinated orders, production and delivery

From specification confirmation through production, inspection, packaging and dispatch, we coordinate quantities, packaging and delivery for each order. You can also discuss product-use feedback directly with us.

05 / CONTACT

Contact us

From application location and material selection to slitting and die cutting,
Develop the aluminium foil tape converting and supply solution together.

王俊杰 General Manager

+86 135 3707 3358simon@jiaotaotao.com

JIAOTAOTAO (GUANGDONG) NEW MATERIALS CO., LTD.

TAPE & CONVERTING

Materials that suit your actual process.

If specifications are already available, discuss supply and converting directly. If the material is not yet selected, start with the actual application area and progressively determine the material and converting format.

Contact us

Discuss by email

07 / PRACTICAL ANSWERS

Frequently asked questions

Start with common usage symptoms to find practical approaches to application, converting and assembly. Follow established safety procedures when operating equipment.

What should I do if aluminium foil tape lifts soon after application to ducts?

Stop the equipment first and check oily dirt, condensation and differences in joint height, ensuring connectors are secure. Once the surface is clean and completely dry, apply a model suited to the conditions in sections so both sides of the tape make full contact, then press the edges. If joints still move after restart, address supports and connections first instead of concealing the problem with more layers.

How can excessive wrinkles around round pipes or elbows be reduced?

Shorten each application length and follow the contour section by section without stretching foil around bends. Press gradually from the bonded side towards the other, avoiding sharp creases across gaps. When changing strip width or overlap direction, retain the original coverage requirements and check that edges and overlaps are truly bonded.

What should I do if aluminium foil tape comes off immediately on a damp surface?

Distinguish residual cleaning water from ongoing condensation and stop repeated taping on wet surfaces. Eliminate the moisture source and apply only when the surface is clean and fully dry. Observe whether condensation returns under operating conditions. Persistent moisture requires correction of insulation or operating conditions, not just tape coverage.

How can I prevent overlaps opening repeatedly after duct vibration?

Stop the equipment and check seam displacement and loose support. Restore the specified structural connection first. Remove failed tape and contamination, dry the surface and rearrange application and overlap, then check changes after restarting. Tape serves only the confirmed covering function, not structural pipe fixing.

What if moisture still enters around the edges after a covering repair?

Check for application on a damp substrate, lifted edges and moisture coming from behind the covering. Address the moisture source and unstable substrate first. Remove failed patches and reapply to a sound, dry surface. Persistent leaks require the appropriate repair method; surface covering is not a universal waterproofing solution.

Should more layers be added if continuity is unstable after electronic bonding?

Do not add layers first. Qualified personnel should separately inspect the foil surface, adhesive layer, overlap and actual contact face on a de-energised, isolated sample. Confirm the connection path and assembly support. Clean, dry, flatten and press the foil again, then retest by the original method. Validate electrical connection and shielding separately; layer count is not the criterion.