After cleaning and drying, apply in sections along the seam so the tape contacts both surfaces firmly, reducing unsupported spans and lifted edges.
Secure duct joint connectors and supports first, then remove oily dirt, debris and condensation. Apply aluminium foil progressively along the joint outline, ensuring a continuous bonding surface on both sides of each covering strip. Press edges evenly and do not bridge open joints without support.
After restarting, inspect overlaps and edges from a safe position. If seams still move with vibration, correct connections and supports rather than adding tape layers. Aluminium foil covering does not provide pressure-retaining or load-bearing pipe repair.
Moisture-protection coverage in non-food-contact kitchen areas
Finish covering edges along dry surfaces to reduce repeated moisture entry through poorly bonded areas.
In specified non-food-contact kitchen areas requiring moisture protection, slit aluminium foil tape to the actual coverage width. Clean and fully dry the surface, then apply from one side. Press edges and overlaps carefully to avoid sealing moisture and contaminants beneath the covering.
For persistent condensation, water ingress or loose surfaces, address the moisture source and substrate before restoring coverage. Moisture-resistant bonding is not equivalent to long-term immersion waterproofing and must not serve as a direct food-contact layer.
Remove loose material before covering the local surface, bonding the patch to sound, dry material around it.
For local damage on non-load-bearing surfaces suitable for tape application, first remove debris and loose portions while retaining a stable, intact surrounding bonding area. Make covering strips or patches to the contour and smooth from the intact surface towards the covering area to reduce repeated edge lifting.
After coverage, check for voids, lifted edges and further changes in the original damaged area. For load-bearing, pressurized, continuously leaking or safety-related structures, use the appropriate repair method rather than replacing structural repair with aluminium foil tape.
Selective shielding coverage in electronic assembly
Make patches to the specified shielding outline, preparing contact positions and functional clearances in advance.
Convert specified electronics shielding areas into slit strips or die-cut aluminium foil pieces, retaining interface and hole clearances. Smooth and press down section by section from a common reference to reduce foil wrinkles and assembly interference.
Qualified personnel should check the electrical paths through the foil, adhesive layer and overlap interfaces separately on de-energised, isolated samples before assembly and shielding validation. Conductive acrylic adhesive does not guarantee a reliable connection on every surface.