01 / Product description

Copper foil tape

COPPER FOIL TAPE

Copper foil tape combines a copper foil backing with an acrylic adhesive layer for shielding coverage on electronic components, enclosure seams and designated display areas. Choose non-conductive or conductive adhesive according to the required connection: the former covers areas not relying on through-adhesive conduction, while the latter supports contact paths involving the adhesive. Rolls can be slit into strips or die-cut into contoured patches to coordinate seams, hole clearances and assembly positions.

  • Copper foil backing
  • Choose the adhesive for the conductive path
  • Slitting and die cutting

Conductivity of the copper foil surface does not establish conduction through the adhesive and bonding interface. First identify the coverage area and connection path, then select the adhesive type and converted format.

Supply formats
Jumbo rolls / Master rolls / Slitting / Die cutting
Copper foil series thicknesses
30–200 μmSeries reference range; confirm the precise thickness definition and converting combinations separately.
Copper foil series widths
1–380 mm

02 / APPLICATIONS

Product applications

Explore application, converting and assembly methods for the specific area of use.

Product characteristics

PRODUCT FEATURES
  • Copper foil coverage for defined shielding boundaries

    Apply copper foil within specified areas, arranging edges, corners and joints to define the coverage outline and reduce gaps and wrinkles between separate patches.

  • Distinguish adhesive types and connection paths

    Choose conductive adhesive when continuity through the adhesive layer is required. For foil coverage alone, select a bonding layer suited to the structure, treating secure bonding and electrical continuity separately.

  • Strips and patches to suit the part shape

    Use slit strips for long seams and shaped patches for areas with holes or corners to reduce on-site cutting and application-position variation.

  • Converting and supply coordinated with assembly handling

    Supply can be organised as jumbo rolls, master rolls, slit rolls and die-cut adhesive parts, coordinating material selection, converted outlines and handling on site.

Applications

RANGE OF APPLICATION
  • Transformer shielding bonding

    Arrange coverage outlines around specified shielding areas without changing windings or existing connections. Keep copper foil edges, joints and functional clearances clearly defined.

  • Selective shielding of mobile phone electronic components

    Apply from the positioning end to keep the foil in the target area, reducing skewed small patches, boundary overrun and repeated trimming.

  • Computer enclosure and component seams

    Coordinate strip width and joint positions with assembly movements. At electrical connection points, establish the actual contact path separately for the selected adhesive type.

  • Bonding display components

    Position copper foil to assembly datums, clear of ports and moving parts. Recheck pressure contact, edges and coverage after closing the assembly.

Validate shielding with the seams, connection paths and assembly structure. Where protective earthing or operating current is involved, qualified personnel must validate against equipment design and applicable requirements. Tape must not replace prescribed protective-earth conductors, terminals or current-carrying connections.

03 / TECHNICAL DATA

Product specifications

The following are options in the copper foil tape series. Distinguish foil thickness and adhesive thickness by the specific material construction.

Backing
Copper foil
Adhesive selection
Non-conductive acrylic adhesive / Conductive acrylic adhesive
Series types
Single-/double-conductive types, distinguished by the selected material structure
Series reference thickness range
30–200 μm
Series reference width range
1–380 mm, custom available
Roll length options
25 / 50 m, custom available
Core diameter options
25 / 32 / 38 / 76 mm
Converting support
Slitting / Die cutting / Custom
Supply and converting formats
Jumbo-roll supply / Master-roll supply / Slitting / Die-cutting services
Packaging
Labels / OPP bags / PVC boxes / Cartons / Customisation

04 / WHY JIAOTAOTAO

Why choose us

More than 16 years of industrial tape manufacturing experience,
Connecting materials, converting and delivery at the factory.

JIAOTAOTAO factory exterior and building signage
JIAOTAOTAO · Dongguan manufacturing site

OUR MANUFACTURING BASE

From coating production to finished-product converting.

Coating, drying and winding connect with rewinding, slitting, die cutting, lamination, inspection and packaging to supply roll materials and converted tape parts for industrial applications.

Industrial tape manufacturing experience
16+years
Factory production space
20000㎡
Production sites
3locations
Explore manufacturing capabilities
01 / FACTORY DIRECT

Direct factory supply, direct communication

Discuss materials, specifications and converting requirements directly with production. Coordinate coating and downstream converting together, reducing handovers and connecting purchasing requirements with actual manufacturing.

02 / QUALITY CONTROL

Factory testing room for delivery quality checks

Check material appearance, dimensions and agreed performance items, coordinating finished-product packaging and identification so confirmed requirements are carried through to delivery.

03 / CUSTOM CONVERTING

Custom converting for practical use

Rewinding, slitting, die cutting and lamination support supply as rolls, finished rolls or contoured tape parts, reducing repeated on-site cutting and handling preparation.

04 / ORDER SUPPORT

Coordinated orders, production and delivery

From specification confirmation through production, inspection, packaging and dispatch, we coordinate quantities, packaging and delivery for each order. You can also discuss product-use feedback directly with us.

05 / CONTACT

Contact us

From application location and material selection to slitting and die cutting,
Let's define the copper foil tape converting and supply plan together.

王俊杰 General Manager

+86 135 3707 3358simon@jiaotaotao.com

JIAOTAOTAO (GUANGDONG) NEW MATERIALS CO., LTD.

TAPE & CONVERTING

Materials that suit your actual process.

If specifications are already available, discuss supply and converting directly. If the material is not yet selected, start with the actual application area and progressively determine the material and converting format.

Contact us

Discuss by email

07 / PRACTICAL ANSWERS

Frequently asked questions

Start with common bonding, joint and assembly symptoms to identify practical corrections. Qualified personnel must carry out electrical checks after power disconnection and isolation.

What should I do if copper foil is securely bonded but does not provide the required connection?

On a de-energised, isolated sample, map the connection path through the foil face, adhesive and bonding surface. Non-conductive adhesive cannot provide continuity through the adhesive layer; choose a suitable conductive adhesive if this path is needed. If an insulating film or coating covers the surface, restore the design-specified contact location first. Repeated pressing or layering cannot replace the connection structure.

How should tape be applied at housing corners prone to edge lifting?

Clean and dry contact surfaces, and check whether the strip is too tight or bridges a groove. Let the foil release naturally, apply in sections along the contour and place the tail on a flat area that can be pressed firmly. Close the housing and check for lifting caused by component spring-back or assembly movements.

Can bulges and wrinkles in copper foil be covered with another layer?

First check surface high spots, dust and application direction. Air can be progressively expelled from flat areas not yet fully bonded. Replace sharply creased, damaged or contaminated adhesive sections. Reposition from one end, gradually release and press down. Do not conceal defects with overlapping layers and continue assembly.

How can rework be reduced when small patches repeatedly become misaligned?

Include clearances for holes, interfaces and surrounding components in the die-cut contour, using the same positioning references as the workpiece. Align the positioning end first, then lay the remainder gradually. Replace deformed or contaminated pieces rather than stretching foil into alignment.

Should I use slit rolls or die-cut copper foil patches?

For continuous straight seams, start with slit strips matching the coverage width. Shaped patches are easier to position for repeated holes, corners or irregular areas. Run through the assembly operation on samples to confirm coverage boundaries, handling direction and joint positions before choosing the converting format.