01 / Product description

Thermally conductive double-sided tape

THERMALLY CONDUCTIVE DOUBLE-SIDED TAPE

Modified acrylic adhesive combines double-sided bonding with thermal contact for fixing between heat sinks, chips and LED lighting components. Its soft, conformable characteristics support thickness selection around assembly gaps and contact surfaces. Die cutting to component outlines covers the effective contact area.

  • Modified acrylic adhesive
  • Double-sided thermal bonding
  • Soft and conformable

Glass-fibre cloth provides thin-layer support, while modified acrylic adhesive containing thermally conductive filler provides two-sided bonding and interface heat transfer. Match thermal, bonding and electrical-insulation requirements separately to the actual assembly.

Supply formats
Jumbo rolls / Master rolls / Slitting / Die cutting
Product thickness
100–700 μmSelect according to the specific material, application and converting requirements.
Slit width
1–1240 mm

02 / APPLICATIONS

Product applications

Explore application, converting and assembly methods for the specific area of use.

Product characteristics

PRODUCT FEATURES
  • Modified acrylic adhesive

    Double-sided bonding connects heat sources and cooling components so fixing and contact coverage work at the same interface.

  • Thermal contact support

    Arrange adhesive parts around the effective contact area to reduce the effects of unsupported spans, misalignment and trapped air on the bonding interface.

  • Soft and conformable

    Select the adhesive layer according to contact-surface condition and assembly gaps, and apply evenly using a method permitted for the component.

  • Contour die-cutting support

    Convert adhesive pieces to contact contours with hole clearances to reduce improvised cutting near devices and repeated positioning.

Applications

RANGE OF APPLICATION
  • IC heat-sink fixing

    Arrange the adhesive layer to the heat-sink contact contour. Rule out assembly interference first, then inspect fixing position and contact coverage.

  • Bonding chips and heat sinks

    Select the adhesive layer for both contact surfaces and the design gap. Align first, then bond progressively to reduce local unsupported areas.

  • LED lighting component bonding

    Match the tape part to the heat-generating component outline, retaining holes and functional clearances for both positioning and thermal contact.

  • Thermal assembly for electronics and appliances

    Standardise bonding methods, installation datums and inspection items to connect fixing and thermal contact with complete-equipment assembly.

Glass-fibre cloth, thermal fillers and double-sided adhesive layers together form the thermal bonding construction. Validate heat conduction, adhesion and electrical insulation separately. Visibly secure bonding does not replace heat-dissipation acceptance, and stacking layers is not a universal gap-filling solution. Sample properties must not be generalized to every thickness.

03 / TECHNICAL DATA

Product specifications

Reference data from catalogue page 13, corresponding to the 150μm total-thickness sample in the table. Not guaranteed values for every thickness or model.

Swipe the table sideways to view all specifications and references ↔

Physical properties of the current thermally conductive double-sided tape reference sample
No.NO.Performance propertyPROPERTIESUnitUNITReference valueREFERENCE VALUEReference / EquipmentREFERENCE / EQUIPMENT
01Total Thicknessμm150μmGB7125-1998
02Film Thicknessμm90μmGB7125-1997
03AdhesionG/25mm1200g-1800gGB/T2792-1997
04Tensile StrengthMPa≥ 180GB/T1040.3
06Voltage ResistanceKV4Not listed
07Heat Resistance℃No adhesive residue after 30 minutes at 135℃CE-021 is the constant-temperature chamber equipment ID, not a test standard

Reference tests apply to the samples listed in the table. Heat-test conditions are not continuous operating temperatures; confirm separately for different grades, thicknesses and applications.

Product customization specifications

Backing / Carrier
Glass-fibre cloth
Adhesive-coated sides
Double-sided
Release layer
Removable release film
Colour
Confirm for the selected material and converting solution
Thickness (μm)
100–700 μm, customized to requirements
Width (mm)
1–1240 mm, custom options available
Length (metres)
30 50 Custom
Core diameter (mm)
25 32 38 76 Custom
Adhesive type
Modified acrylic pressure-sensitive adhesive containing ceramic thermally conductive fillers
Related processes
Die cutting Customisation
Packaging
Labels OPP bags PVC boxes Cartons Custom

04 / WHY JIAOTAOTAO

Why choose us

More than 16 years of industrial tape manufacturing experience,
Connecting materials, converting and delivery at the factory.

JIAOTAOTAO factory exterior and building signage
JIAOTAOTAO · Dongguan manufacturing site

OUR MANUFACTURING BASE

From coating production to finished-product converting.

Coating, drying and winding connect with rewinding, slitting, die cutting, lamination, inspection and packaging to supply roll materials and converted tape parts for industrial applications.

Industrial tape manufacturing experience
16+years
Factory production space
20000㎡
Production sites
3locations
Explore manufacturing capabilities
01 / FACTORY DIRECT

Direct factory supply, direct communication

Discuss materials, specifications and converting requirements directly with production. Coordinate coating and downstream converting together, reducing handovers and connecting purchasing requirements with actual manufacturing.

02 / QUALITY CONTROL

Factory testing room for delivery quality checks

Check material appearance, dimensions and agreed performance items, coordinating finished-product packaging and identification so confirmed requirements are carried through to delivery.

03 / CUSTOM CONVERTING

Custom converting for practical use

Rewinding, slitting, die cutting and lamination support supply as rolls, finished rolls or contoured tape parts, reducing repeated on-site cutting and handling preparation.

04 / ORDER SUPPORT

Coordinated orders, production and delivery

From specification confirmation through production, inspection, packaging and dispatch, we coordinate quantities, packaging and delivery for each order. You can also discuss product-use feedback directly with us.

05 / CONTACT

Contact us

From application location and material selection to slitting and die cutting,
Let's define the thermally conductive double-sided tape converting and supply plan together.

王俊杰 General Manager

+86 135 3707 3358simon@jiaotaotao.com

JIAOTAOTAO (GUANGDONG) NEW MATERIALS CO., LTD.

TAPE & CONVERTING

Materials that suit your actual process.

If specifications are already available, discuss supply and converting directly. If the material is not yet selected, start with the actual application area and progressively determine the material and converting format.

Contact us

Discuss by email

07 / PRACTICAL ANSWERS

Frequently asked questions

Start with common usage symptoms to find practical approaches to application, converting and assembly. Follow established safety procedures when operating equipment.

How should incomplete heat-sink contact be investigated?

On de-energised production samples, check flatness, installation references and adhesive thickness, distinguishing steps, unsupported areas and component interference. Clean and dry both surfaces, then bond evenly in a device-permitted manner without forcing fragile devices. Check edge contact and coverage, then compare thermal performance under the established process.

How can bubbles after bonding be reduced?

Check for foreign matter, pressing the whole patch down at once and repeated repositioning. Apply a new sample progressively from an aligned side with uniform pressure, without touching the adhesive. Disassemble a sample if needed to verify contact. Do not puncture bubbles on components or treat an appearance achieved by forceful pressing as acceptance.

Can more layers be added if an assembly gap remains after application?

Do not use stacked layers as a general gap-filling method. Check gap locations, component tolerances and installation datums first. Correct positioning or surface problems, then select thickness or another thermal interface solution within design limits. After reassembly, check position, coverage and thermal results together.

What should I do if the heat sink is securely bonded but temperature rise remains high?

Stop the machine, isolate energy and allow cooling first. Then inspect system factors including positioning, contact coverage, interfaces and airflow under safety procedures. Correct process samples one item at a time with other conditions unchanged. Appropriately qualified personnel should compare results under the same operating conditions. Do not disassemble live equipment or simply replace with thicker tape.

How should tape parts be adjusted if they are too large or cover holes?

Redefine the adhesive-piece shape for the effective contact area and functional clearances. Make samples or die-cut contours off-line rather than cutting directly on chips or circuits. Check holes, boundaries and compression during trial assembly, then reassess bond coverage and thermal performance after confirming the contour.

Can previous heat-dissipation results still be used directly after changing thickness?

Do not retain an earlier conclusion solely because the adhesive type is unchanged. Keep contact area, assembly method and test conditions consistent, recheck gaps, coverage and component position, then compare thermal results. Thickness changes also affect assembly relationships; tighter or softer contact alone does not establish improvement.